Laboratory Centrifuge Model 800 (China)

♡ Add to wishlist

The Model 800 is a benchtop, low-speed laboratory centrifuge listed with adjustable speed, a 6 × 20 mL capacity and a maximum relative centrifugal force of 1790 × g. It is intended for compatible laboratory separation workflows where the supplied rotor and operating specifications meet the procedure's requirements.For a laboratory planning routine sample preparation, checking the required centrifugal force and tube fit helps determine whether...

Rs.12,500.00 Rs.14,500.00
Brand:
Lab Store
Tags:
Benchtop Centrifuge, Laboratory Centrifuge, Low Speed Centrifuge, Model 800, Sample Separation

The Model 800 is a benchtop, low-speed laboratory centrifuge listed with adjustable speed, a 6 × 20 mL capacity and a maximum relative centrifugal force of 1790 × g. It is intended for compatible laboratory separation workflows where the supplied rotor and operating specifications meet the procedure's requirements.

For a laboratory planning routine sample preparation, checking the required centrifugal force and tube fit helps determine whether this unit suits the workflow.

Listed specifications

  • Model: 800.
  • Configuration: benchtop laboratory centrifuge.
  • Speed: adjustable, with a listed upper speed of approximately 4000 rpm; confirm the actual operating range.
  • Capacity: 6 × 20 mL, as listed.
  • Maximum RCF: 1790 × g, as listed.
  • Origin: China, as listed.

Rotor and tube compatibility

Confirm the supplied rotor, tube dimensions, adapters and permitted tube materials before purchase. The stated capacity does not establish compatibility with every 20 mL tube. RPM and RCF are different specifications; use settings appropriate to the rotor and your laboratory's validated procedure.

Details to confirm

The earlier description ambiguously calls approximately 4000 rpm the starting speed. Confirm the minimum and maximum speed, control accuracy and timer settings against the supplied unit's documentation. Power requirements, rotor type, lid-lock or interlock features, braking behaviour and noise level are not documented here.

Confirm whether tubes and adapters are included. Manufacturer identity, warranty and dimensions are not supplied. The earlier 1 kg weight is not identified as net or packed weight.

Professional use and care

Follow the manufacturer's instructions for installation, balancing, loading, cleaning and maintenance. Do not open the lid while the rotor is moving. Suitability for clinical samples or a specific diagnostic workflow must be established by the user's laboratory, including appropriate containment and handling requirements.