Analytical Balance AS-214 China 0.1mg to 200gm (0.0001g-200g)

♡ Add to wishlist

The AS-214 analytical balance is listed with a 200 g maximum capacity and 0.1 mg (0.0001 g) readability for laboratory sample and reagent weighing. Its listed glass draft shield and backlit LCD display support an organized benchtop weighing workflow.Place your weighing container on the pan, tare the balance and add your sample within the capacity limit, following the supplied instructions and your laboratory's procedure.Listed specifications...

Rs.119,800.00 Rs.130,000.00
Brand:
Lab Store
Tags:
0.1mg Readability, 200g Balance, Analytical Balance, AS-214, Laboratory Weighing

The AS-214 analytical balance is listed with a 200 g maximum capacity and 0.1 mg (0.0001 g) readability for laboratory sample and reagent weighing. Its listed glass draft shield and backlit LCD display support an organized benchtop weighing workflow.

Place your weighing container on the pan, tare the balance and add your sample within the capacity limit, following the supplied instructions and your laboratory's procedure.

Listed specifications

  • Model: AS-214.
  • Maximum capacity: 200 g.
  • Readability: 0.0001 g (0.1 mg).
  • Display: backlit LCD.
  • Glass draft shield.
  • Calibration: external, as listed.
  • Weighing units listed include g, mg, ct and oz.
  • Pan diameter: approximately 80 mm, as listed.
  • Power supply: 220 V AC, 50 Hz, as listed; confirm the supplied unit's rating.
  • Origin: China, as listed.

Measurement performance

Readability is the displayed increment, not a guarantee of accuracy or the minimum usable sample weight. The earlier listing states repeatability of ±0.0001 g and linearity of ±0.0002 g; confirm these values against the supplied model's manufacturer documentation. A draft shield reduces exposure to air currents but does not eliminate all environmental effects.

Applications and supplied configuration

Laboratory sample preparation, teaching exercises and compatible routine quality-control weighing. Suitability for a specific method depends on its measurement requirements and the balance's verified performance.

RS232 output is described as model-dependent and is not confirmed as included. Confirm manufacturer identity, calibration-weight inclusion, accessories, overload-protection details, warranty and any required calibration documentation before ordering.

Setup and care

Follow the manufacturer's levelling, warm-up, calibration and cleaning instructions. Use a stable location with controlled drafts and vibration. Do not exceed the stated capacity.